Water Systems
Watermaker pressure too low — air leak on intake hose
Janne
Problem
Our watermaker wouldn’t reach normal operating pressure. It stayed around 30–40 bar instead of the usual 55–60. It ran but didn’t produce fresh water.
Fix
- 1
First I assumed the high-pressure pump was failing.
- 2
I spent way too long reading the manual and checking the internet.
- 3
While checking the seawater intake line I noticed tiny air bubbles in the clear hose. The hose clamp on the intake fitting was slightly loose.
- 4
I tightened it and the air bubbles disappeared. Pressure immediately went back to normal and the watermaker started producing water again.
Questions and comments
Log in to commentJanne
Gruezi
Finn
I has a similar issue. Great fix!
Stefan
Ich habe zur Spülung des Vorfilters und zur Entlüftung des Systems eine zusätzliche Verbindung von der bordseitigen Druckwasserversorgung eingerichtet. Diese führt über einen Absperrhahn und einen Aktivkohlefilter in den Saugbereich der Hochdruckpumpe, genauer gesagt zwischen Sauganschluss und Saugfilter. Damit kann ich vor dem Start der Hochdruckpumpe Frischwasser ins System einspeisen, den Vorfilter rückspülen und gleichzeitig die Saugleitung vollständig entlüften.